Creyogenics Tanks And Tankers Production

Our cryogenic semi-trailers are designed according to ADR requirements and manufactured to store cryogenic liquids at maximum capacity.


Cryogenic Semi-Trailers (LNG - LIN - LOX – LAR)

Cryogenic tank manufacturing for storage and transportation of liquified natural gas (LNG / -150°C), liquefied oxygen (LOX), liquefied nitrogen (LIN), liquefied argon (LAR)

Carbon Steel outer tank and stainless-steel inner tank (1.4307 / 1.4301)

Multi-layered isolation of inner tank and vacuumed interlayer for best performance for storing of LNG/LIN/LOX/LAR cryogenic liquified gases.

Our cryogenic semi-trailers are designed according to ADR requirements and manufactured to store cryogenic liquids at maximum capacity

Semi-trailers and tanks on trucks are equipped with ADR compatible valves and piping and be customised with optimum pumps on customer request.

All of the design and product tests are approved and inspected by international and accepted third party certification companies.

Standards

EN 13530, ASME, ADR, GOST, 2007/46/EC

Design Temperature

– 196 / +50 °C

Materials (Inner Tank)

Stainless Steel EN 10028-7

Materials (Outer Tank)

Carbon Steel / Stainless Steels EN 10028-7, EN 10028-3, EN 10025

Insulation

Super Isolation and Vacuum

LNG - LIN - LOX - LAR ISO TANK Containers

Cryogenic ISO tank containers are used for storage and transportation of liquified natural gas (LNG / -150°C), liquefied oxygen (LOX), liquefied nitrogen (LIN), liquefied argon (LAR)

Carbon Steel outer tank and stainless-steel inner tank (1.4307 / 1.4301)

Multi-layered isolation of inner tank and vacuumed interlayer for best performance for storing of LNG/LIN/LOX/LAR cryogenic liquified gases.

Our ISO Tanks are manufactured in 20’, 30’ and 40’ dimensions according to ADR, RID requirements.

All of the design and product tests are approved and inspected by international and accepted third party certification companies.

Standards

EN 13530, ASME, ADR, GOST, 2007/46/EC

Design Temperature

– 196 / +50 °C

Materials (Inner Tank)

Stainless Steel EN 10028-7

Materials (Outer Tank)

Carbon Steel / Stainless Steels EN 10028-7, EN 10028-3, EN 10025

Supporting Structure

Carbon Steel

Insulation

Super Isolation and Vacuum

Dimensions

20′, 30′, 40′

Operating Pressure

On demand


LNG - LIN - LOX - LAR Horizontal & Vertical Storage Tanks

Cryogenic stationary tanks are used for storage and transportation of liquified natural gas (LNG / -150°C), liquefied oxygen (LOX), liquefied nitrogen (LIN), liquefied argon (LAR)

These types of tanks are generally designed and manufactured to operate between 2-37 bar.

Our tanks are manufactured by using carbon steel (1.4307) for outer tank and stainless steel (1,4301) inner tank and insulated with Cryogenic perlite and vacuum to store cryogenic liquids such as LNG/LIN/LOX/LAR

All of the design and product tests are approved and inspected by international and accepted third party certification companies.

Standards

EN 13458, ASME, GOST, AD2000, PED

Design Temperature

– 196 / +50 °C

Materials (Inner Tank)

Stainless Steel EN 10028-7

Materials (Outer Tank)

Carbon Steel / Stainless Steels EN 10028-7, EN 10028-3, EN 10025

Insulation

Super Isolation and Vacuum / Cryogenic perlite and vacuum

Operating Pressure

2-37 bar

Capacity

1 – 500m³

Dimensions

On demand

 

LCO2 Storage Tanks (vacuum-insulated)

Vertical and stationary vacuum-insulated pressure vessels for storage of LCO2 at any pressure rate and capacity on customer demand. Our tanks are designed and manufactured for best performance to provide low heat transfer to minimise evaporation rates.

 

Standards

EN 13458, PED

Design Temperature

– 196 / +50 °C

Materials (Inner Tank)

Stainless Steel EN 10028-7

Materials (Outer Tank)

Carbon Steel / Stainless Steels EN 10028-7, EN 10028-3, EN 10025

Insulation

Cryogenic perlite and vacuum insulation

Operating

On demand

Capacity

On demand

Dimensions

On demand

 

LCO2 Trailers and Bobtails

LCO2 tanks designed according to country specific road regulations and operating pressures at maximum capacities.

Standards

EN 14398, EN 14025, ADR, TPED

Design Temperature

– 40 / +50 °C

Inner Tank Materials

Carbon Steel EN 10028-3 / Duplex Stainless Steel

Outer Jacket

Aluminium

Insulation

Polyurethane

Operating Pressure

On demand

 

Evaporatör

Evaporators designed for requested operating pressure, capacity and usage type on customer demands

 

Standards

EN, PED

Operating Temperature

40bar – 300bar

Capacity

50 – 4000 Nm³/h

Dimensions

On demand

 

Gas and Air Tanks

Gas and Air tanks designed for requested operating pressure, capacity and usage type on customer demands.

 

LPG Tanks (Aboveground or Underground)

LPG tanks can be used as underground or aboveground tanks according to preference of usage area.  P355 boiler plate to EN10028-2 is a fine-grained steel for used in pressure vessels, heat exchangers and reactors. P355 is one of our most popular pressure vessel steels. Our tanks are equipped with necessary accessories for intended use.

All design and test procedures are confirmed by globally accepted third party certification bodies

  1.  

Standards

EN 13445, ASME, GOST, PED

Design Temperature

– 60 / +50 °C

Materials

Carbon Steel P355 EN 10028-3

Operating Pressure

On demand

  1.  

LPG Trailers and Bobtails

P355 boiler plate to EN10028-2 is a fine-grained steel for used in pressure vessels, heat exchangers and reactors. P355 is one of our most popular pressure vessel steels. These types of tanks are generally designed and manufactured to operate at 17.5 bar. Our tanks are equipped with necessary accessories for intended use. All design and test procedures are confirmed by globally accepted third party certification bodies

 

Standards

EN 13445, EN 12493, EN 12252 ASME, ADR, GOST

 

Design Temperature

– 60 / +50 °C

 

Materials

Carbon Steel P355 EN 10028-3