Creyogenics Tanks And Tankers Production
Our cryogenic semi-trailers are designed according to ADR requirements and manufactured to store cryogenic liquids at maximum capacity.
Cryogenic Semi-Trailers (LNG - LIN - LOX – LAR)
Cryogenic tank manufacturing for storage and transportation of liquified natural gas (LNG / -150°C), liquefied oxygen (LOX), liquefied nitrogen (LIN), liquefied argon (LAR)
Carbon Steel outer tank and stainless-steel inner tank (1.4307 / 1.4301)
Multi-layered isolation of inner tank and vacuumed interlayer for best performance for storing of LNG/LIN/LOX/LAR cryogenic liquified gases.
Our cryogenic semi-trailers are designed according to ADR requirements and manufactured to store cryogenic liquids at maximum capacity
Semi-trailers and tanks on trucks are equipped with ADR compatible valves and piping and be customised with optimum pumps on customer request.
All of the design and product tests are approved and inspected by international and accepted third party certification companies.
Standards | EN 13530, ASME, ADR, GOST, 2007/46/EC |
Design Temperature | – 196 / +50 °C |
Materials (Inner Tank) | Stainless Steel EN 10028-7 |
Materials (Outer Tank) | Carbon Steel / Stainless Steels EN 10028-7, EN 10028-3, EN 10025 |
Insulation | Super Isolation and Vacuum |
LNG - LIN - LOX - LAR ISO TANK Containers
Cryogenic ISO tank containers are used for storage and transportation of liquified natural gas (LNG / -150°C), liquefied oxygen (LOX), liquefied nitrogen (LIN), liquefied argon (LAR)
Carbon Steel outer tank and stainless-steel inner tank (1.4307 / 1.4301)
Multi-layered isolation of inner tank and vacuumed interlayer for best performance for storing of LNG/LIN/LOX/LAR cryogenic liquified gases.
Our ISO Tanks are manufactured in 20’, 30’ and 40’ dimensions according to ADR, RID requirements.
All of the design and product tests are approved and inspected by international and accepted third party certification companies.
Standards | EN 13530, ASME, ADR, GOST, 2007/46/EC |
Design Temperature | – 196 / +50 °C |
Materials (Inner Tank) | Stainless Steel EN 10028-7 |
Materials (Outer Tank) | Carbon Steel / Stainless Steels EN 10028-7, EN 10028-3, EN 10025 |
Supporting Structure | Carbon Steel |
Insulation | Super Isolation and Vacuum |
Dimensions | 20′, 30′, 40′ |
Operating Pressure | On demand |
LNG - LIN - LOX - LAR Horizontal & Vertical Storage Tanks
Cryogenic stationary tanks are used for storage and transportation of liquified natural gas (LNG / -150°C), liquefied oxygen (LOX), liquefied nitrogen (LIN), liquefied argon (LAR)
These types of tanks are generally designed and manufactured to operate between 2-37 bar.
Our tanks are manufactured by using carbon steel (1.4307) for outer tank and stainless steel (1,4301) inner tank and insulated with Cryogenic perlite and vacuum to store cryogenic liquids such as LNG/LIN/LOX/LAR
All of the design and product tests are approved and inspected by international and accepted third party certification companies.
Standards | EN 13458, ASME, GOST, AD2000, PED |
Design Temperature | – 196 / +50 °C |
Materials (Inner Tank) | Stainless Steel EN 10028-7 |
Materials (Outer Tank) | Carbon Steel / Stainless Steels EN 10028-7, EN 10028-3, EN 10025 |
Insulation | Super Isolation and Vacuum / Cryogenic perlite and vacuum |
Operating Pressure | 2-37 bar |
Capacity | 1 – 500m³ |
Dimensions | On demand |
LCO2 Storage Tanks (vacuum-insulated)
Vertical and stationary vacuum-insulated pressure vessels for storage of LCO2 at any pressure rate and capacity on customer demand. Our tanks are designed and manufactured for best performance to provide low heat transfer to minimise evaporation rates.
Standards | EN 13458, PED |
Design Temperature | – 196 / +50 °C |
Materials (Inner Tank) | Stainless Steel EN 10028-7 |
Materials (Outer Tank) | Carbon Steel / Stainless Steels EN 10028-7, EN 10028-3, EN 10025 |
Insulation | Cryogenic perlite and vacuum insulation |
Operating | On demand |
Capacity | On demand |
Dimensions | On demand |
LCO2 Trailers and Bobtails
LCO2 tanks designed according to country specific road regulations and operating pressures at maximum capacities.
Standards | EN 14398, EN 14025, ADR, TPED |
Design Temperature | – 40 / +50 °C |
Inner Tank Materials | Carbon Steel EN 10028-3 / Duplex Stainless Steel |
Outer Jacket | Aluminium |
Insulation | Polyurethane |
Operating Pressure | On demand |
Evaporatör
Evaporators designed for requested operating pressure, capacity and usage type on customer demands
Standards | EN, PED |
Operating Temperature | 40bar – 300bar |
Capacity | 50 – 4000 Nm³/h |
Dimensions | On demand |
Gas and Air Tanks
Gas and Air tanks designed for requested operating pressure, capacity and usage type on customer demands.
LPG Tanks (Aboveground or Underground)
LPG tanks can be used as underground or aboveground tanks according to preference of usage area. P355 boiler plate to EN10028-2 is a fine-grained steel for used in pressure vessels, heat exchangers and reactors. P355 is one of our most popular pressure vessel steels. Our tanks are equipped with necessary accessories for intended use.
All design and test procedures are confirmed by globally accepted third party certification bodies
Standards | EN 13445, ASME, GOST, PED |
Design Temperature | – 60 / +50 °C |
Materials | Carbon Steel P355 EN 10028-3 |
Operating Pressure | On demand |
LPG Trailers and Bobtails
P355 boiler plate to EN10028-2 is a fine-grained steel for used in pressure vessels, heat exchangers and reactors. P355 is one of our most popular pressure vessel steels. These types of tanks are generally designed and manufactured to operate at 17.5 bar. Our tanks are equipped with necessary accessories for intended use. All design and test procedures are confirmed by globally accepted third party certification bodies
Standards | EN 13445, EN 12493, EN 12252 ASME, ADR, GOST
|
Design Temperature | – 60 / +50 °C
|
Materials | Carbon Steel P355 EN 10028-3
|